0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FL75L10 A

FL75L10 A

  • 厂商:

    DELTA(台达)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
FL75L10 A 数据手册
FL75R10A Filter Module 75Vdc Input Maximum, 10A Maximum FEATURES  ROHS Compliant  Small size: 50.8 mm x 27.9 mm x 11.7mm (2.0” x 1.1” x 0.46“)  Industry standard footprint and pin-out  Optimized for use with high frequency board mounted DC/DC converters  ISO 9001, TL 9000, ISO 14001, QS9000, OHSAS18001 certified manufacturing facility  Printed-circuit board mountable Delphi Series Filter Module - FL75L10A 75Vdc max input, 10A max output current The Delphi series FL75L10A filter module is the latest offering from a world leader in power systems technology and manufacturing -- Delta Electronics, Inc. This filter module is designed to reduce the conducted common-mode and differential-mode noise on input or output lines of high-frequency switching power supplies and has a maximum current rating of 10A. It has the industry standard footprint and pin-out. With creative design technology and optimization of component placement, Delphi FL75L10A filter module possesses outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating conditions. APPLICATIONS  Common-mode and differential-mode filtering of power supply dc input and output line DATASHEET DS_FL75L10_ 07162007  Computer application  Communications equipment SPECIFICATIONS GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Input voltage, continuous Typical 0~75V Output current Ta=70°C, no airflow 10A Input voltage, transient Typical 100V Output current Ta=85°C, no airflow 8A Operation case temperature Typical -40℃ ~ 110℃ Common-mode Insertion Loss 50Ω circuit, 500 kHz (Typ) 30dB Storage temperature Typical -55℃ ~ 125℃ Differential-mode Insertion Loss 50Ω circuit, 500 kHz (Typ) 25dB Size (2.0”x1.1”x0.46”) 50.8 mm x27.9 mm x11.7 mm ELECTRICAL CHARACTERISTICS CURVES Figure 1: Typical common-mode insertion loss in a 50Ω circuit Figure 2: Typical differential-mode insertion loss in a 50Ω circuit Internal Schematics Figure 3: Internal schematics 2 THERMAL CONSIDERATIONS THERMAL CURVES Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. OUT Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. GND Thermal Testing Setup Delta’s filter modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. Figure 5: Temperature measurement location The allowed maximum hot spot temperature is defined at 110℃ FL75L10 (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vin = 48V (Either Orientation) Output Current(A) 12 10 The following figure shows the wind tunnel characterization setup. The filter module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is 6.35mm (0.25”). 8 6 Natural Convection 4 Thermal Derating 100LFM 2 Heat can be removed by increasing airflow over the module. Figure 4 shows maximum output is a function of ambient temperature and airflow rate. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. 0 50 55 60 65 70 75 80 85 Ambient Temperature (℃) Figure 6: Output Current vs. Ambient Temperature and Air Velocity @ Vin = 48V (Either Orientation) PWB FACING PWB MODULE AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 50.8 (2.0”) AIR FLOW 10 (0.4”) Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 4: Wind tunnel test setup figure dimensions are in millimeters and (inches). 3 APPLICATION Note: C2 through C5 can be 0.01μ F to o.1μ F. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value indicated in the power module data sheet. Figure 7: Recommended schematic when used as the input filter to a high-frequency dc-to-dc converter Note: Vdc input(+) and Vdc input(-) planes should overlay each other, as should the Vi(+) and Vi(-) planes, as should the Vout(+) and Vout(-) planes. Avoid routing signals or planes under the power module or the filter module. Ensure all connections are low impedance. Figure 8: Recommended layout when used as the input filter to a high-frequency dc-to-dc converter 4 APPLICATION (Con.) Note: : C2 through C5 and C6 through C9 can be 0.01μ F to o.1μ F. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value indicated in the power module datasheet. Figure 9: Recommended schematic of filter module with two power modules 5 Figure 10 shows the experimental result obtained by using this filter module, together with the recommended external components shown in Figures 7 and 8. The Q48SR3R335NR module is one of the Delphi series quarter brick 3.3V, 35A DCDC converters. Measured noise is greatly dependent on layout, grounding, cable orientation, and load characteristics and the variation is possible from various application conditions. Figure 10: Q48SR3R335NR A conducted noise with FL75L10 input filter MECHANICAL DRAWING Top View Side View Bottom View Dimensions are in millimeter and (inches). Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in) RECOMMENDED HOLE PATTERN Dimensions are in millimeter and (inches). Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in) 6 PART NUMBERING SYSTEM FL 75 L 10 Product Family Input Voltage Product Series Output Current FL- Input EMI Filter 75- 0 ~ 75V L – Industry standard 10 - 10A A Space Option Code A - Standard Functions B - 0.18” pin option MODEL LIST Module Name Input Voltage (max.) Current Rating (max.) FL75L10 A 100V 10A FL75L10 B 100V 10’A CONTACT: www.deltaww.com/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: DCDC@delta-corp.com Europe: Telephone: +31-20-655-0967 Fax: +31-20-655-0999 Email: DCDC@delta-es.com Asia & the rest of world: Telephone: +886 3 4526107 ext 6220-6224 Fax: +886 3 4513485 Email: DCDC@delta.com.tw WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. 7
FL75L10 A 价格&库存

很抱歉,暂时无法提供与“FL75L10 A”相匹配的价格&库存,您可以联系我们找货

免费人工找货